What is the biggest kiln on 120v household current?

 

COMPANY SQUARE KILNS SHELF SIZE RECEPTACLE MAX TEMP
Paragon S1310 Trio 10” x 16" Shelf 5-15R 1700° F
Paragon FiberFuse 16 15” Shelf 5-15R 1700° F
Paragon CS-16S 15” Shelf 5-20R 1700° F
Paragon Fusion 16 15” Shelf 5-20R 1700° F
Paragon CS-16D 15” Shelf 5-20R 1700° F
Jen-Ken ProFusion Fiber 16 15” Shelf 5-15R 1700° F
Olympic Quatro 16 15” Shelf 5-20R 1700° F
Olympic Quatro 16 TLC 15” Shelf 5-20R 1700° F
Evenheat Studio Pro 17 RM 16” Shelf 5-20R 1650° F
Evenheat Studio Pro 17 STP 16” Shelf 5-20R 1650° F
Olympic Square 186GFE 16” Shelf 5-20R 1700° F
Olympic Square 186GFETLC 16” Shelf 5-20R 1700° F
COMPANY ROUND KILNS SHELF SIZE RECEPTACLE MAX TEMP
Paragon Max 119 10" Shelf 5-20R 2300° F
Evenheat HF 810 10.25" Shelf 5-20R 2300° F
Evenheat RM II 810 10.25" Shelf 5-20R 2200° F
Evenheat Hot Shot 12" Shelf 5-15R 1650° F
Evenheat GT 14-6 12" Shelf 5-15R 1650° F
Paragon Fusion 7 13" Shelf 5-15R 1700° F
Jen-Ken Fiber 15 "Bonnie Glo" 13" Shelf 5-15R 1700° F
Jen-Ken Fiber 15 "Bonnie Glo" Tilt 13" Shelf 5-15R 1700° F
Jen-Ken Fiber 15 "Bonnie Glo" Tall 13" Shelf 5-15R 1700° F
Jen-Ken AF3P 15/6 13" Shelf 5-15P 1700° F
Olympic 186GFE 15.5” Shelf 5-20R 1700° F
COMPANY KNIFE KILNS DEPTH RECEPTACLE MAX TEMP
Evenheat KH 414 13.5" 5-15R 2200° F
Paragon KM14T 14.5"  5-20R 2350° F
Paragon KM18T 18"  5-20R 2350° F
Evenheat KH 418 18"  5-15R 2200° F
Paragon PMT10 9" 5-20R 2350° F

Now that we have a great list of kilns that will all work on 120v household current, we need to make sure your plug matches your receptacle. 

Most homes in the U.S. are wired with a combination of 15-amp and 20-amp, 120-volt circuits. Because 15-amp receptacles (5-15R) can be used with 20-amp circuits, most of the receptacles you see in homes are the standard 15-amp variety, with two slots and a U-shaped grounding hole. Twenty-amp receptacles (5-20R) have a horizontal slot branching off one of the vertical slots. Plugs designated as 20 amp will not fit into 15-amp outlets. 

The final important piece of information when looking at 120v kilns is amperage. You will need to be certain you have a breaker that meets the amperage requirements for your kiln as most of the 5-20R kilns require a dedicated circuit. Without a 20 amp breaker, your kiln will not reach the desired temperatures to fuse glass. Older homes, apartments, and mobile homes will have 15 amp breakers. Please check your breaker box carefully prior to ordering. Kiln Frog, LLC cannot be held responsible for kilns ordered that cannot operate at full temperatures due to electrical issues on site.

 If you have questions, we always recommend talking to a licensed electrician.